ADVANCED CONTROL PAD SYSTEM™
Relieves surgical team from manual stimulation of pressure points.
Delivers periodic massage action automatically.
Stimulates hip and thigh pressure points during surgery.
Enhances patient comfort and safety.
OPTIMAL POSITIONING
Advanced Control Pad System™ with Tempur-Med® technology supports patient comfort and safety
Customized support pads enhance patient positioning and are mounted on the radiolucent, carbon composite frame
MINIMIZED BLOOD LOSS
Reduces vena caval compression
Minimizes epidural venus bleeding
Dramatically improves visualization
360° ROTATION
Facilitates safe and efficient rotation of patient.
Rapid horizontal axis rotation in prone or supine positions
Allows unique, multiplanar, intraoperative images of spine and pelvis.
Rotational Capability The rotational capability facilitates 360˚ spinal fusions without the need to remove the patient for repositioning. After the anterior fusion is complete, the Jackson Spinal Surgery Top is applied and the patient is rotated 180˚. The Radiolucent Imaging Top is removed, providing surgical access to the posterior spine and pelvis.
| SPECIFICATIONS |
|
|
| MODULAR TOP |
JACKSON TOP |
IMAGING TOP |
| Table top length |
84 in. (213 cm) |
84 in. (213 cm) |
| Table top width |
17 in. (43 cm) |
21.5 in. (54.6 cm) |
| Patient Weight Capacity |
500lb. (227 kg) |
500lb. (227 kg) |
| MODULAR BASE |
|
| Table Top Floor Height |
27 in.-48 in. (69 cm) – (122 cm) |
| Base Width |
32 in. (81 cm) |
| Base Length |
102 in. (259 cm) |
| Retractable Base Length |
64 in. (163 cm) |
| Trendelenburg/Reverse
Trendelenburg |
10° |
| Lateral Tilt |
25° |
| Patient Weight Capacity |
500 lb. (227 kg) |
STANDARD EQUIPMENT
Patient Safety Straps
T Pins
H Frames
Patient Chest Pad
Articulating Arm Board, w/ brackets, pair
Patient Head Support Plate (Face Plate)
Leg Board w/ pad - 2
 |
A/P
Imaging A/P intraoperative radiographic image with C-Arm.
Patient is prone on the Jackson Spinal Surgery Table Top. |
 |
| Lateral
Imaging Saggital images can be obtained for lateral
view without C-Arm rotation. Table rotation is faster and provides
less potential for contamination of sterile field by the C-Arm
. |
Cervical Traction Vector Adjustor
Leg Sling
Modular Table Equipment Cart
Patient Care Kits
Advanced Control Pad System™ w/ Mizuho OSI Tempur-Med® Technology
ACP Thigh Pads - right / left
ACP Hip Pads
Quick Connect ACP Tubing (1 Case)
ORDERING INFORMATION
5943AP—Jackson Spinal Surgery Top w/ Advanced Control Pad System™.
100/120 VAC 50/60 Hz
5927—Radiolucent Imaging Top w/ Tempur-Med® 2 in. Table Pad
5803—Advanced Control Modular Base, 120 VAC 60 Hz
5803I—Advanced Control Modular Base, 230 VAC 50/60 Hz
5943API—Jackson Spinal Surgery Top w/ Advanced Control Pad System™, 230 VAC 50/60 Hz
OPTIONAL ACCESSORIES
5319G — Radiolucent Wilson Frame w/ ShearGuard®
5321G — Radiolucent Wilson Frame for JST w/
ShearGuard®
5322 — Patient Care Kit, RWF, 6/cs
5839 — A/P Cassette Tray
5855-830 — Side Rail Adaptor for 5927 Radiolucent Imaging Top
5888 — Retractor Adaptor
5894 — Shoulder Rest Set
5873 — Coupler Assembly II (may be used with
MAYFIELD® Headrest)
5846 — Spinal Top Adaptor Brackets for 5873 - pr.
5979-1 — Cervical Management Base Unit
5879-2 — Anterior Extension Positioner, 5 in.
pad w/ bladder
5880-09 — Supine Operating Top, short
5808 — Patient Care Kit, Jackson, case of 6
6910-3003 — DORO® Skull Clamp - Aluminum
6910-3034 — DORO® Skull Clamp - Radiolucent
5873-300 — Radiolucent DORO® Adaptor for Coupler II
5979-300 — Radiolucent DORO® Adaptor for Cervical Base
6946 — OSI Tempur-Med® Pillow
(for positioning and use in sling)
5356 — Pivoting Arm Board w/ 2 in. pad
5857 — Cross Arm Support w/ 1 in. pad
5393 — Clarke Socket
5364 — Lateral Arm Board Set w/ 2 in. pads
Mizuho OSI thanks Rodger P. Jackson, M.D., F.A.C.S. for his
assistance in the development of the Jackson Spinal Surgery
and Radiolucent Imaging Tops.

MIZUHO OSI
30031 Ahern Avenue
Union City, CA 94587
(510) 429-1500
(800) 777-4674
Fax (888) 329-4674
Fax (510) 429-8500
MIZUHOSI.COM
NEWHIPNEWS.COM
NEWSPINENEWS.COM
ISO certified by TUV Rheinland of North America and this table is ETL listed and CE approved.

Note: Mizuho OSI is constantly improving its products, all specifications
are subject to change without notice. Mizuho OSI is a Delaware Corporation. Manufactured
in the USA. ©Mizuho OSI
Tempur-Med® is a registered Trademark of Tempur-Pedic® Medical, Inc. DORO® is a registered trademark of pro med instruments GmbH.
NW0414 REV C 10/08